Tank Battery grounding and LPS have now been added to the NFPA 780 2023 Edition. If you want information on tank farm inspections, select a button below. See the Commercial page—recommended maintenance.
N 7.8.1 Protection of tank batteries shall include the protection of associated equipment.
N 7.8.2 Strike termination methods shall be provided in accordance with 7.3.3 and 7.6.3.2.
N 7.8.3* Site appurtenances - such as flare stacks, separators,
and heater treaters - outside of a zone of protection shall be protected.
N 7.8.4 Ground-level potential equalization shall be established within the tank battery through the interconnection of metallic components, underground piping, and grounding systems.
N 7.8.5* In locations where direct strikes or arcing is likely to occur, engineering methods shall be used to minimize the accumulation of flammable vapors in areas where a source of ignition is likely to be present.
N 7.8.6 Surge protection shall comply with 7.3.6.